Участник
G4BVE
UK/Shrewsbury
Динамика баллов
Суммарные баллы за туры с течением времени (в хронологическом порядке).
История туров
| Тур | Сезон | Класс | Баллы | Ошибка FREQ (Hz) | Ошибка PULSE (ms) | Ошибка PPS (ms) |
|---|---|---|---|---|---|---|
| Tour 1 | 2026-2027 | PRO | 157,20 | -0.140 | +0.05 | +0.45 |
| Tour 6 | 2026 H1 | PRO | 113,10 | -0.038 | +0.33 | +6.404 |
| Tour 5 | 2026 H1 | PRO | 99,70 | +0.019 | -23.372 | -0.34 |
| Tour 4 | 2026 H1 | PRO | 163,10 | +0.374 | -0.6 | -0.2 |
| Tour 3 | 2026 H1 | PRO | 103,20 | -0.085 | -0.3 | +3.6 |
| Tour 2 | 2026 H1 | PRO | 101,30 | -0.090 | +2.5 | +1.5 |
| Tour 1 | 2026 H1 | PRO | 74,20 | +0.111 | -1 | -7 |
Турнирная таблица сезона
| Сезон | Категория | Баллы | Лучшие N | Сертификат |
|---|---|---|---|---|
| 2026-2027 | Общий зачёт | 157,20 | 1 | — |
| 2026-2027 | Кубок несущей (FREQ) | 50,00 | 1 | — |
| 2026-2027 | Кубок PPS (PPS) | 51,30 | 1 | — |
| 2026-2027 | Кубок импульса (PULSE) | 55,90 | 1 | — |
| 2026 H1 | Общий зачёт | 654,60 | 6 | |
| 2026 H1 | Кубок несущей (FREQ) | 240,70 | 6 | — |
| 2026 H1 | Кубок PPS (PPS) | 194,20 | 6 | — |
| 2026 H1 | Кубок импульса (PULSE) | 219,70 | 6 | — |
Архив методов
Методы измерения, которые этот участник решил опубликовать.
Tour 1 — 2026-2027
Audio from the Elad fed to the PC and oscilloscope. Pulse measurements on oscilloscope and frequency measurements on SpectrumLab. System checked using waveforms from generator also locked to RFzero reference.
Tour 6 — 2026 H1
Measure frequency offset using SpectrumLab. Scope trigger 1pps from RFzero. Rx locked to 10MHz from GPSDO Measure pulse width and UTC offset on oscilloscope. Calibration using generator, counter and calibration transmissions.
Tour 5 — 2026 H1
Measure frequency offset using SpectrumLab. Scope trigger 1pps from RFzero. Rx locked to 10Mhz from GPSDO Measure pulse width and UTC offset on oscilloscope. Calibration using generator, counter and calibration transmissions.
Tour 4 — 2026 H1
Measure frequency offset using SpectrumLab. Scope trigger 1pps from RFzero. Measure pulse width and UTC offset on oscilloscope. Calibration using generator, counter and calibration transmissions.
Tour 3 — 2026 H1
Measure frequency offset using SpectrumLab. Scope trigger 1pps from RFzero. Measure pulse width and UTC offset on oscilloscope. Offset calibration using locked Siglent SDG1062X and confirmed using RWM.
Tour 2 — 2026 H1
Audio from Edlad FMD Duo fed to PC and oscilloscope. Frequency offset measured on Spectrum Lab. Peak_f readings written to a file every few seconds and post processed. Pulse width and UTC offset measured on oscilloscope triggered at 1pps from the RFzero. Screen grabs taken from the oscilloscope for later analysis. Latency through the Elad measured by generating local RF pulses from a Siglent SGS1062X generator which is locked to the RFZero 10MHz reference.
Tour 1 — 2026 H1
Frequency: RSPDx GPS locked. SpectrumLab on PC. Pulse width: Oscilloscope. UTC offset: RSPdx latency calibrated by generating GPS locked pulses with the Siglent SDG1062X and delay measured on oscilloscope. No doppler correction applied.